Print PRINT
X
Phaco Technology: INFINITI® Vision System

Optimize Your Energy Solutions

Anticipating Every Move. Now That’s Smart

Featuring OZil® Intelligent Phaco software upgrades, the INFINITI® Vision System puts optimized OZil® torsional emulsification at your fingertips. With enhanced fluidic management and surgical control, the INFINITI® Vision System delivers the strategic advantage in customized phaco procedures.

INFINITI® SYSTEM FEATURES

Energy Solutions Fluidics INTREPID® AutoSert® IOL Injector INTREPID® Micro-Coaxial System Ergonomics
OZil® Torsional Handpiece INTREPID® PLUS Fluidics Management System (FMS) Surgeon Control Torsional Phaco with Micro-Coaxial Staff-Friendly Console
OZil® Intelligent Phaco (OZil® IP) INTREPID® Micro-Coaxial System Improved Wound Integrity Touchscreen Design
Custom Power Modulations Custom Fluidics Software Versatility & Control Enhanced Footswitch
Remote Control
View Important Product Information for
INFINITI® Vision System +

INFINITI® Vision System

Caution:
Federal law restricts this device to sale by, or on the order of, a physician.

As part of a properly maintained surgical environment, it is recommended that a backup IOL Injector be made available in the event the AutoSert® IOL Injector Handpiece does not perform as expected.

Indication:
The INFINITI® Vision System is indicated for emulsification, separation, and removal of cataracts, the removal of residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intra-ocular lens injection. The INTREPID® AutoSert® IOL Injector Handpiece is intended to deliver qualified AcrySof® intraocular lenses into the eye following cataract removal.

The following system modalities additionally support the described indications:

  • Ultrasound with UltraChopper® Tip achieves the functionality of cataract separation.
  • AquaLase® Liquefracture Device achieves the functionality for removal of residual cortical material and lens epithelial cells.
  • The INTREPID® AutoSert® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The INTREPID® AutoSert® IOL Injector Handpiece is indicated for use with ACRYSOF® lenses SN60WF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof® lenses that are specifically indicated for use with this inserter, as indicated in the approved labeling of those lenses.

Warnings:
Appropriate use of INFINITI® Vision System parameters and accessories is important for successful procedures. Use of low vacuum limits, low flow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to sufficiently aspirate viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in significant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage.

Adjusting aspiration rates or vacuum limits above the preset values, or lowering the IV pole below the preset values, may cause chamber shallowing or collapse which may result in patient injury.

When filling handpiece test chamber, if stream of fluid is weak or absent, good fluidics response will be jeopardized. Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye.

Ensure that tubings are not occluded or pinched during any phase of operation.

The consumables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of consumables and handpieces other than those manufactured by Alcon may affect system performance and create potential hazards.

AEs/Complications:
Use of the NeoSoniX®, OZil® torsional, U/S, or AquaLase® handpieces in the absence of irrigation flow and/or in the presence of reduced or lost aspiration flow can cause excessive heating and potential thermal injury to adjacent eye tissues.

Attention:
Refer to the directions for use for a complete listing of indications, warnings and precautions.

INFINITI® Vision System

Caution:
Federal law restricts this device to sale by, or on the order of, a physician.

As part of a properly maintained surgical environment, it is recommended that a backup IOL Injector be made available in the event the AutoSert® IOL Injector Handpiece does not perform as expected.

Indication:
The INFINITI® Vision System is indicated for emulsification, separation, and removal of cataracts, the removal of residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intra-ocular lens injection. The INTREPID® AutoSert® IOL Injector Handpiece is intended to deliver qualified AcrySof® intraocular lenses into the eye following cataract removal.

The following system modalities additionally support the described indications:

  • Ultrasound with UltraChopper® Tip achieves the functionality of cataract separation.
  • AquaLase® Liquefracture Device achieves the functionality for removal of residual cortical material and lens epithelial cells.
  • The INTREPID® AutoSert® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The INTREPID® AutoSert® IOL Injector Handpiece is indicated for use with ACRYSOF® lenses SN60WF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof® lenses that are specifically indicated for use with this inserter, as indicated in the approved labeling of those lenses.

Warnings:
Appropriate use of INFINITI® Vision System parameters and accessories is important for successful procedures. Use of low vacuum limits, low flow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to sufficiently aspirate viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in significant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage.

Adjusting aspiration rates or vacuum limits above the preset values, or lowering the IV pole below the preset values, may cause chamber shallowing or collapse which may result in patient injury.

When filling handpiece test chamber, if stream of fluid is weak or absent, good fluidics response will be jeopardized. Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye.

Ensure that tubings are not occluded or pinched during any phase of operation.

The consumables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of consumables and handpieces other than those manufactured by Alcon may affect system performance and create potential hazards.

AEs/Complications:
Use of the NeoSoniX®, OZil® torsional, U/S, or AquaLase® handpieces in the absence of irrigation flow and/or in the presence of reduced or lost aspiration flow can cause excessive heating and potential thermal injury to adjacent eye tissues.

Attention:
Refer to the directions for use for a complete listing of indications, warnings and precautions.