DVO conçus pour optimiser la protection de la cornée


Les options d'Alcon ont une variété de propriétés cohésives et dispersives pour assurer un volume suffisant à chaque étape de l'intervention.

A shot of three Alcon Ophthalmic Viscosurgical Devices. Inside of the tubes of each device, an image is shown of these OVDs being used during a surgical procedure.

Le sulphate de chondroïtine assure un
revêtement supérieur de l’endothélium1-4

Dark blue circle with the number “-1” in the middle to indicate the charge for sodium hyaluronate. 2 blue interlocking circles both with the numbers “-1” in the middle to indicate chondroitin sulphate’s double negative charge. There is a plus sign between the dark blue circle and the 2 blue interlocking circles to illustrate that when sodium hyaluronate is combined with chondroitin sulphate, a triple negative charge occurs.

Le sulfate de chondroïtine comporte une double charge négative. Sa combinaison avec l’hyaluronate de sodium produit une triple charge négative. Il en résulte une amélioration de l’adhésion au tissu endothélial qui est chargé positivement.1-4*

 

* Comparaison avec des  DVO à l’hyaluronate de sodium seul

Les DVO contenant du sulfate de chondroïtine améliorent la rétention du viscoélastique2*

 

Les produits viscoélastiques au sulfate de chondroïtine offrent une rétention et une épaisseur de revêtement supérieures sur l’endothélium stressé par un débit élevé. Il en résulte une réduction de la perte de cellules endothéliales et de l’œdème cornéen.1-3,5-7

A visual comparison between OVDs that do not contain chondroitin sulphate and OVDs that do contain chondroitin sulphate. The OVDs that do not contain chondroitin sulphate are PROVISC, Healon, Healon 5 and Amvisc. The OVDs that do contain chondroitin sulphate are VISCOAT and DisCoVisc. OVDs with chondroitin sulphate retained 325 µm under high flow while others retained 0 µm.

Débit d’aspiration de 60 mL/min

University of Texas Southwestern : Étude in vivo chez l’animal par microscopie confocale (Adaptée par Alcon; reconstructions représentatives par CMTF) 
 * Comparaison avec des solutions au HaNA seul. 
† Les marques de commerce appartiennent à leurs propriétaires respectifs. 

Alcon’s Viscoat OVD product and product box on a blue circle background.
Alcon’s Viscoat OVD product and product box on a blue circle background.
ViscoatMD
Alcon’s DuoVisc OVD product and product box on a blue circle background.
Alcon’s DuoVisc OVD product and product box on a blue circle background.
ProViscMD
Alcon’s DisCoVisc OVD product and product box on a blue circle background.
Alcon’s DisCoVisc OVD product and product box on a blue circle background.
DuoViscMD
Alcon’s DisCoVisc OVD product and product box on a blue circle background.
Alcon’s DisCoVisc OVD product and product box on a blue circle background.
DisCoViscMD

La versatilité de performance avec le système viscoélastique DuoViscMD 8

3 blue interlocking circles. Inside the first circle white text reads “Pre Phaco.” Inside the middle circle white text reads “Phaco.” Inside the last circle white text reads “IOL Delivery.”

DuoViscMD, d'un produit cohésif et d'un produit dispersif, répond à vos besoins et à vos préférences durant les interventions, vous permettant d’adopter une variété de techniques chirurgicales. En suivant la méthodologie éprouvée, vous maximisez les avantages et minimisez les inconvénients des deux produits.8

Une plage de volumes permet de couvrir
chaque étape de l’intervention

 

La quantité de DVO requise dépend d’une variété de facteurs, dont l’intervention, la technique et les préférences du chirurgien. De ce fait, les DVO d’Alcon sont disponibles en plusieurs volumes permettant de répondre à vos besoins – même au-delà de 1 mL.

Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.85 ml of ProVisc.
Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.85 ml of ProVisc.
Small
ViscoatMD 0.35 ml
ProViscMD 0.40 ml
Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.55 ml of ProVisc.
Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.55 ml of ProVisc.
Large
ViscoatMD 0.50 ml
ProViscMD 0.55 ml
Alcon’s DuoVisc OVD product box. This product contains 0.35 ml of Viscoat and 0.40 ml of ProVisc.
Alcon’s DuoVisc OVD product box. This product contains 0.35 ml of Viscoat and 0.40 ml of ProVisc.
Extra Large
ViscoatMD 0.50 ml
ProViscMD 0.85 ml
Alcon’s DisCoVisc product box. This product contains 1ml of DisCoVisc.
Alcon’s DisCoVisc product box. This product contains 1ml of DisCoVisc.
DisCoViscMD 1 ml

Les DVO d’Alcon sont de qualité constante et sont très appréciés des chirurgiens9,10

 

Exigez les DVO de haute qualité Alcon pour obtenir des résultats optimaux pour vos patients.

Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.55ml of ProVisc.
Alcon’s DuoVisc OVD product box. This product contains 0.50 ml of Viscoat and 0.55ml of ProVisc.

DuoViscMD est le produit d’Alcon le mieux vendu9

A white box with text inside that reads “160 million Alcon OVDs used worldwide.” A blue diamond with a white syringe icon inside sits on top of the white box.
A white box with text inside that reads “160 million Alcon OVDs used worldwide.” A blue diamond with a white syringe icon inside sits on top of the white box.

Les chirurgiens du monde entier utilisent les DVO d’Alcon depuis plus de 25 ans

La trousse Custom-PakMD est le moyen le plus efficace d'approvisionner votre salle d'opération en consommables

Alt text

Instructions d’utilisation (IFU)


Pour la liste complète des indications, des contre-indications et des mises en garde, rendez-vous au site ifu.alcon.com et consultez les instructions d’utilisation des produits pertinents.

Alcon Experience Academy


Un contenu de formation pertinent par des leaders d'opinion de l'industrie

Références
1. Glasser DB, Katz HR, Boyd JE, et al. Protective effects of viscous solutions in phacoemulsification and traumatic lens implantation. Arch Ophthalmol. 1989;107(7):1047-1051. 
2. Petroll WM, Jafari M, Lane SS, Jester JV, Cavanagh HD. Quantitative assessment of ophthalmic viscosurgical retention using in vivo confocal microscopy. J Cataract Refract Surg. 2005;31(12):2363-2368.
3. Poyer JF, Chan KY, Arshinoff SA. New method to measure the retention of viscoelastic agents on a rabbit corneal endothelial cell line after irrigation and aspiration. J Cataract Refract Surg. 1998;24(1):84-90.
4. Lehmann R, Brint S, Stewart R, et al. Clinical comparison of ProVisMD and Healon in cataract surgery. J Cataract Refract Surg. 1995;21(5):543-547.
5. Papaconstantinou D, Karmiris T, Diagourtas A, Koutsandrea C, Georgalas I. Clinical trial evaluating ViscoatMD and Visthesia ophthalmic viscosurgical devices in corneal endothelial loss after cataract extraction and intraocular lens implantation. Cutan Ocul Toxicol. 2014;33(3):173-180.
6. Koch D, Liu JF, Glasser DB, Merin LM, Haft E. A comparison of corneal endothelial changes after use of Healon or Viscoat during phacoemulsification. Am J Ophthalmol. 1993;115(2):188-201.
7. Moschos MM, Chatziralli IP, Sergentanis TN. Viscoat versus Visthesia during phacoemulsification cataract surgery: corneal and foveal changes. BMC Ophthalmol. 2011 Apr 29;11:9. doi: 10.1186/1471-2415-11-9.
8. Arshinoff SA. Dispersive-cohesive viscoelastic soft shell technique. J Cataract Refract Surg. 1999 Feb;25(2):167-73. doi: 10.1016/s0886-3350(99)80121-7.
9. Alcon, données internes, 2021.
10. DisCoViscMD, instructions d’utilisation.


Veuillez consulter les instructions d’utilisation des produits pertinents pour la liste des indications, des contre-indications et des mises en garde.