Take a closer look at the EX-PRESS® Glaucoma Filtration Device with live action videos and animations of the device’s engineering and implantation — including live surgeries narrated by surgeons who have embraced this innovative alternative to the trabeculectomy.

Featured doctors are paid consultants of Alcon Laboratories.

Select a resource type:
 
Case Videos

Watch this video for a step-by-step demonstration of the implantation procedure.

This animation goes step by step through glaucoma filtration surgery with the EX-PRESS® Glaucoma Filtration Device.
Arrow right
 
This animation breaks down the implantation procedure of the EX-PRESS® Glaucoma Filtration Device step by step. [1:25]
 

EX-PRESS® Glaucoma Filtration Device – Crandall

Dr. Alan Crandall performs glaucoma filtration surgery.
Arrow right
 
Watch as Dr. Alan Crandall performs the EX-PRESS® Glaucoma Filtration Device implantation procedure. [12:15]
 

Watch as Dr. Ike Ahmed takes you step-by-step through a live EX-PRESS® Glaucoma Filtration Device implantation, offering pearls along the way.

Dr. Ike Ahmed walks you through the implantation procedure for the EX-PRESS® Glaucoma Filtration Device.
Arrow right
 
Watch Dr. Ike Ahmed perform live surgery using the EX-PRESS® Glaucoma Filtration Device. [11:01]
 

Watch this animation to see how simple it can be to combine glaucoma filtration and cataract surgeries.

Cataract surgery and glaucoma filtration surgery in a single procedure.
Arrow right
 
The order of the steps is a little different when you combine EX-PRESS® Glaucoma Filtration Device implantation with cataract surgery, but the procedures are similar. Watch this animation to see how it's done. [5:26]
 

Live EX-PRESS® Glaucoma Filtration Device/IOL Implantation

Dr. Garry Condon performs a combined cataract surgery and glaucoma filtration surgery.
Arrow right
 
Watch Dr. Garry Condon combine glaucoma filtration and cataract surgeries. [10:42]
 

Enjoy the Benefits of Lumenal Control

Sign up and we’ll contact you right away with more information about the EX-PRESS® Glaucoma Filtration Device and other Alcon products.

*Name

 

*Email

 

*City

 

*State

 

 

*Zip Code:

*Hospital Affiliation

 

*Phone

 

How many filtration surgeries do
you perform a month?

 

 

Questions/Comments




 

*Required Field

Privacy Statement
Alcon will use this information to
respond to your request. Please
read our Privacy Policy for more
information.

I have read and agreed to the
Alcon Privacy Policy.

 

 
X
View Important Product Information for:
EX-PRESS® Glaucoma Filtration Device
+

EX-PRESS® Glaucoma Filtration Device

CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

INDICATION: The EX-PRESS® Glaucoma Filtration Device is intended to reduce intraocular pressure in glaucoma patients where medical and conventional surgical treatments have failed.

GUIDANCE REGARDING THE SELECTION OF THE APPROPRIATE VERSION: Prior clinical studies were not designed to compare between the various versions of the EX-PRESS® Glaucoma Filtration Device. The selection of the appropriate version is according to the doctor’s discretion.

CLINICAL STUDY INFORMATION: A clinical study was performed with the EX-PRESS® Glaucoma Filtration Device versions R-30 and R-50. The study was a prospective, open-label multi-center study of 113 open angle glaucoma patients with a follow-up period of one year. Results indicated an 80.4% overall success for the per-protocol cohort (R-30 and R-50, n=58) at one year, where overall success was defined as an IOP reduction greater than 20% from baseline with or without medications. Results indicated a 75.9% overall success for the per-protocol cohort (R-30 and R-50, n=58) at one year, where overall success was defined as an IOP of less than 21 mmHg with or without medications. The mean IOP reduction at one year was 33.8%. The percentage reduction from baseline was greater than 28% for the R-30 version and greater than 40% for the R-50 version.

The overall average number of glaucoma medications dropped significantly from 1.55 pre-operative to 0.52 medications at one-year postoperative.

The clinical study was not designed to compare between the various versions of the EX-PRESS® Glaucoma Filtration Device. The selection of the appropriate version is according to the doctor’s discretion. The most commonly reported adverse events included the need for further filtering surgery, device explantation, bleb revision and iris touch. Reasons for device explantation included flat anterior chamber with hypotony, device exposure from erosion, and poor efficacy. Other adverse events such as, but not limited to, corneal and retinal complications, uveitis, and significant reduction in visual acuity, may occur as well.

CONTRAINDICATIONS: The use of this device is contraindicated if one or more of the following conditions exist:

  • Presence of ocular disease such as uveitis, ocular infection, severe dry eye, severe blepharitis.
  • Pre-existing ocular or systemic pathology that, in the opinion of the surgeon, is likely to cause postoperative complications following implantation of the device.
  • Patients diagnosed with angle closure glaucoma.

WARNINGS/PRECAUTIONS: The use of this device is contraindicated if one or more of the following conditions exist:

  • The surgeon should be familiar with the directions for use.
  • The integrity of the package should be examined prior to use and the device should not be used if the package is damaged and sterility is compromised.
  • This device is for single use only.
  • MRI of the head is permitted, however not recommended, in the first two weeks post implantation.

ATTENTION: Reference the Directions for Use labeling for a complete listing of indications, warnings, precautions, complications and adverse events.

EX-PRESS® Glaucoma Filtration Device

CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician.

INDICATION: The EX-PRESS® Glaucoma Filtration Device is intended to reduce intraocular pressure in glaucoma patients where medical and conventional surgical treatments have failed.

GUIDANCE REGARDING THE SELECTION OF THE APPROPRIATE VERSION: Prior clinical studies were not designed to compare between the various versions of the EX-PRESS® Glaucoma Filtration Device. The selection of the appropriate version is according to the doctor’s discretion.

CLINICAL STUDY INFORMATION: A clinical study was performed with the EX-PRESS® Glaucoma Filtration Device versions R-30 and R-50. The study was a prospective, open-label multi-center study of 113 open angle glaucoma patients with a follow-up period of one year. Results indicated an 80.4% overall success for the per-protocol cohort (R-30 and R-50, n=58) at one year, where overall success was defined as an IOP reduction greater than 20% from baseline with or without medications. Results indicated a 75.9% overall success for the per-protocol cohort (R-30 and R-50, n=58) at one year, where overall success was defined as an IOP of less than 21 mmHg with or without medications. The mean IOP reduction at one year was 33.8%. The percentage reduction from baseline was greater than 28% for the R-30 version and greater than 40% for the R-50 version.

The overall average number of glaucoma medications dropped significantly from 1.55 pre-operative to 0.52 medications at one-year postoperative.

The clinical study was not designed to compare between the various versions of the EX-PRESS® Glaucoma Filtration Device. The selection of the appropriate version is according to the doctor’s discretion. The most commonly reported adverse events included the need for further filtering surgery, device explantation, bleb revision and iris touch. Reasons for device explantation included flat anterior chamber with hypotony, device exposure from erosion, and poor efficacy. Other adverse events such as, but not limited to, corneal and retinal complications, uveitis, and significant reduction in visual acuity, may occur as well.

CONTRAINDICATIONS: The use of this device is contraindicated if one or more of the following conditions exist:

  • Presence of ocular disease such as uveitis, ocular infection, severe dry eye, severe blepharitis.
  • Pre-existing ocular or systemic pathology that, in the opinion of the surgeon, is likely to cause postoperative complications following implantation of the device.
  • Patients diagnosed with angle closure glaucoma.

WARNINGS/PRECAUTIONS: The use of this device is contraindicated if one or more of the following conditions exist:

  • The surgeon should be familiar with the directions for use.
  • The integrity of the package should be examined prior to use and the device should not be used if the package is damaged and sterility is compromised.
  • This device is for single use only.
  • MRI of the head is permitted, however not recommended, in the first two weeks post implantation.

ATTENTION: Reference the Directions for Use labeling for a complete listing of indications, warnings, precautions, complications and adverse events.