MyAlcon | ํ•œ๊ตญ

์ด ํŽ˜์ด์ง€๋Š” ํ•œ๊ตญ์—์„œ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๋‹ค๋ฅธ ์–ธ์–ด์˜ ๊ฒฝ์šฐ ์•„๋ž˜์—์„œ ๋‹ค๋ฅธ ๊ตญ๊ฐ€๋ฅผ ์„ ํƒํ•˜์‹ญ์‹œ์˜ค.

๋‹ค๋ฅธ ๊ตญ๊ฐ€ ์„ ํƒ

AutonoMeยฎ Delivery System

 

The ultimate experience of control at every step1

AutonoMeยฎ Delivery System

 

The ultimate experience of control at every step1

 

์„œ์ „์˜ ์†์— ํŽธ์•ˆํ•˜๊ฒŒ ๋งž๋„๋ก Single-handed design์œผ๋กœ ์„ค๊ณ„๋จ1-3

 

  • ์—ฌ๋Ÿฌ ์ˆ˜์ˆ  ๊ธฐ๋ฒ•์— ์ ํ•ฉํ•˜๋„๋ก ์ž์—ฐ์Šค๋Ÿฝ๊ฒŒ ์„ค๊ณ„๋˜์—ˆ์œผ๋ฉฐ ์ฃผ ์ž…๋ ฅ์ด ํ•„์š”ํ•˜์ง€ ์•Š์Œ

 

  • Single-handed design

 

  • ๋…ธ์ค„ํŒ ๋ฐฉํ–ฅ์„ ์ •๋ฐ€ํ•˜๊ฒŒ ์ œ์–ดํ•˜์—ฌ ์บก์Аํ˜• ๋ฐฑ์— IOL์ด ์ผ๊ด€๋˜๊ฒŒ ์‚ฝ์ž…๋  ์ˆ˜ ์žˆ์Œ

์„œ์ „์˜ ์†์— ํŽธ์•ˆํ•˜๊ฒŒ ๋งž๋„๋ก Single-handed design์œผ๋กœ ์„ค๊ณ„๋จ1-3

 

  • ์—ฌ๋Ÿฌ ์ˆ˜์ˆ  ๊ธฐ๋ฒ•์— ์ ํ•ฉํ•˜๋„๋ก ์ž์—ฐ์Šค๋Ÿฝ๊ฒŒ ์„ค๊ณ„๋˜์—ˆ์œผ๋ฉฐ ์ฃผ ์ž…๋ ฅ์ด ํ•„์š”ํ•˜์ง€ ์•Š์Œ

 

  • Single-handed design

 

  • ๋…ธ์ค„ํŒ ๋ฐฉํ–ฅ์„ ์ •๋ฐ€ํ•˜๊ฒŒ ์ œ์–ดํ•˜์—ฌ ์บก์Аํ˜• ๋ฐฑ์— IOL์ด ์ผ๊ด€๋˜๊ฒŒ ์‚ฝ์ž…๋  ์ˆ˜ ์žˆ์Œ

 

Preserves Wound Integrity4*

AutonoMeยฎ features a proprietary depth guard1,4

  • ์ฃผ๋ณ€ ์กฐ์ง์˜ ์ŠคํŠธ๋ ˆ์Šค์™€ ์†์ƒ์„ ์ค„์ž„
  • ๋…ธ์ถœ ์‚ฝ์ž… ๊นŠ์ด ์ œ์–ด
  • ์ตœ์†Œํ™”๋œ ์ ˆ๊ฐœ ํ™•๋Œ€
  • ๋…ธ์ค„ ํŒ ๋ถ„ํ• ์— ๋Œ€ํ•œ ๋” ํฐ ์ €ํ•ญ
  • ์บก์А ๋ฐฑ์— ๋” ์ •ํ™•ํ•˜๊ฒŒ ์‚ฝ์ž… ๊ฐ€๋Šฅ

 

 

*Ex-vivo, exploratory laboratory study performed on 32 human cadaver eyes.

๊ฒ€์€์ƒ‰ ๋ฐฐ๊ฒฝ ์•ž์— ์žˆ๋Š” AutonoMe ๋…ธ์ฆ ํŒ์˜ ํด๋กœ์ฆˆ์—… ์ƒท์ž…๋‹ˆ๋‹ค. ์žฅ์น˜ ์œ„์— ํŒŒ๋ž€์ƒ‰ ์›์ด ๋ฐฐ์น˜๋˜์–ด ๋…ธ์ฆ ํŒ์— ์ฃผ์˜๋ฅผ ๊ธฐ์šธ์ž…๋‹ˆ๋‹ค.

AutonoMeยฎ is ready to use in 3 simple steps1

AutonoMe Delivery ์‹œ์Šคํ…œ์˜ ๊ทธ๋ฆผ์ž…๋‹ˆ๋‹ค. ๊ฒ€์€์ƒ‰ ํ™”์‚ดํ‘œ๊ฐ€ โ€œViscoelastic Portโ€์™€ โ€œFill viscoelastix to nozzle tipโ€ ๋ฌธ๊ตฌ์™€ ํ•จ๊ป˜ ์žฅ์น˜์™€ ๋…ธ์ฆํŒ์„ ๊ฐ€๋ฆฌํ‚ต๋‹ˆ๋‹ค ํŒŒ๋ž€์ƒ‰ ์˜จ๋„๊ณ„ ์•„์ด์ฝ˜.

AutonoMe Delivery ์‹œ์Šคํ…œ์„ ์žก๊ณ  ์žˆ๋Š” ์†์˜ ๊ทธ๋ฆผ์ž…๋‹ˆ๋‹ค. ์žฅ์น˜์˜ ์นดํŠธ๋ฆฌ์ง€์—์„œ ๋–จ์–ด์ง„ ๊ณณ์„ ๊ฐ€๋ฆฌํ‚ค๋Š” ๊ฒ€์€์ƒ‰ ํ™”์‚ดํ‘œ๋Š” ๋‹น๊ธฐ๋Š” ๋™์ž‘์„ ๋‚˜ํƒ€๋ƒ…๋‹ˆ๋‹ค.

AutonoMe Delivery ์‹œ์Šคํ…œ์„ ์žก๊ณ  ์žˆ๋Š” ์†์˜ ๊ทธ๋ฆผ์ž…๋‹ˆ๋‹ค. ๊ฒ€์€์ƒ‰ ํ™”์‚ดํ‘œ๊ฐ€ ์žฅ์น˜ ์ชฝ์„ ๊ฐ€๋ฆฌํ‚ค๋ฉฐ ์•„๋ž˜๋กœ ๋ฐ€๋ฆฌ๋Š” ๋™์ž‘์„ ๋‚˜ํƒ€๋ƒ…๋‹ˆ๋‹ค.ํŒŒ๋ž€์ƒ‰ ์‹œ๊ณ„ ์•„์ด์ฝ˜.

Learn how to use the AutonoMeยฎ Delivery System.

 
 

AutonoMeยฎ is Pre-Loaded with

Clareonยฎ IOL 

 

Clareonยฎ IOL offers outstanding refractive outcomes and unsurpassed clarity that lasts.6-14

AutonoMeยฎ is Pre-Loaded with Clareonยฎ IOL 

 

Clareonยฎ IOL offers outstanding refractive outcomes and unsurpassed clarity that lasts.6-14

 

์‚ฌ์šฉ์„ค๋ช…์„œ (IFU)

 

์ ์‘์ฆ๊ณผ ๊ธˆ๊ธฐ, ๊ฒฝ๊ณ  ๋“ฑ์˜ ์ „์ฒด ๋ชฉ๋ก์„ ํ™•์ธํ•˜๋ ค๋ฉด ifu.alcon.com ์›น์‚ฌ์ดํŠธ์— ๋ฐฉ๋ฌธํ•ด์„œ ํ•ด๋‹น ์ œํ’ˆ์˜ ์‚ฌ์šฉ์„ค๋ช…์„œ๋ฅผ ์ฐธ์กฐํ•˜์‹œ๊ธฐ ๋ฐ”๋ž๋‹ˆ๋‹ค.

Alcon Experience Academy

 

์—…๊ณ„ ์ „๋ฌธ๊ฐ€๋“ค์ด ์ž‘์„ฑํ•œ ๊ด€๋ จ ๊ต์œก์ž๋ฃŒ๋ฅผ ์ด์šฉํ•˜์‹œ๋ ค๋ฉด

References
1. Clareonยฎ AutonoMeยฎ Directions for Use. 
2. Nozzle Preference and Delivery System Performance Study between AutonoMe and UltraSert V3.5 - TDOC 0053876 
3. Verification Report, IOL Inserter Plunger Speed Testing. Alcon internal document REF-04194. 
4. Liu J, Wolfe P, Hernandez V, Kohnen T. Comparative assessment of the corneal incision enlargement of 4 preloaded IOL delivery systems. J Cataract Refract Surg. 2020 Jul;46(7):1041-1046. 
5. Alcon Data on File. TDOC-0054429. 
6. Werner L, Thatthamla I, Ong M, et al. Evaluation of clarity characteristics in a new hydrophobic acrylic IOL. J Cataract Refract Surg. 2019;45:1490-1497.
7. Clareonยฎ IOL Directions for Use.
8. Alcon Data on File, 2017. [TDOC-0050244] 
9. Alcon Data on File, 2017. [TDOC-0054028] 
10. Alcon Data on File, 2017. [TDOC-0053564] 
11. Alcon Data on File, 2017. [TDOC-0053584] 
12. Alcon Data on File, 2020. [TDOC-0057291] 
13. Stanojcic N, Oโ€™Brart D, Hull C, et al. Visual and refractive outcomes and glistenings occurrence after implantation of 2 hydrophobic acrylic aspheric monofocal IOLs. J Cataract Refract Surg. 2020;46(7):986-994. 
14. Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethyl methacrylate. J Cataract Refract Surg. 2020;46(5):682-687. 

 

Please refer to the relevant product direction for use for list of indications, contraindications and warnings.

์ด ์ œํ’ˆ์€ '์˜๋ฃŒ๊ธฐ๊ธฐ'์ด๋ฉฐ, '์‚ฌ์šฉ์ƒ์˜ ์ฃผ์˜์‚ฌํ•ญ'๊ณผ '์‚ฌ์šฉ๋ฐฉ๋ฒ•'์„ ์ž˜ ์ฝ๊ณ  ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค
SY60WF์™ธ 1๊ฑด ์ธ๊ณต์ˆ˜์ •์ฒด , ํ—ˆ๊ฐ€๋ฒˆํ˜ธ : ์ˆ˜ํ—ˆ 19-171ํ˜ธ